Page Header
Home/News Product Info Tech Support Sales/Ordering Contact Info
 
Demo Transmitter Facility for the RFC-1/B

Sine Systems has a demo system to give you a better idea of how the RFC-1/B works. Our demo "transmitter" facility has two 25 kW FM transmitters; a main and an auxiliary. To operate the demo facility:

  • Call (615) 777-RFC1
  • After the RFC-1 answers you will hear the word "Enter."
  • Enter the Main Security Code: 12345678. After you do this the RFC-1 will say "This is RFC-1/B" and you have access to the system.

To read a telemetry channel (meter), enter a two-digit channel number such as 00. If you wish to control equipment at the facility, enter the Control Security Code: 66. Here is a list of what is available at the demo facility:

Channel
Telemetry/Status Description Lower/Off (*) Raise/On (#)
00
Transmitter 1 – Filaments Off On
01
Transmitter 1 – Plate Voltage Off On
02
Transmitter 1 – Plate Current unused unused
03
Transmitter 1 – Power Output Lower Raise
04
Transmitter 2 – Filaments Off On
05
Transmitter 2 – Plate Voltage Off On
06
Transmitter 2 – Plate Current unused unused
07
Transmitter 2 – Power Output Lower Raise
08
Antenna Relay Position Position B Position A
09
AC Power unused unused
10
Diesel Generator manual off manual on
11
Room Temperature unused unused
12
Smoke Alarm unused unused

To speed up the demo, the filaments have an "instant on" so there is no filament time delay. Still, the filaments must be turned on before the plate voltage can be turned on. This demo will automatically initialize with Transmitter 1 on the air Don't worry about how you leave things when you're finished experimenting. System programming has been inhibited.

To demonstrate the feature that causes the telemetry to be spoken automatically if there is a significant change (>10% of full scale), we've made the generator take 5 seconds to start (hit 10#, then wait 5 seconds). This feature is really handy for situations when you're waiting for something to happen such as a transmitter to power on.

Note that you don't have to wait for the telemetry to be spoken before control can take place. You can execute the sequence "05*08#00#01#" as quickly as you can push the keys. Some transmitters, however, may require delays.

The demo transmitter is set up for voice and data operation--voice is tried first. To demo in data mode, set your communications software to 2400 baud/8 data bits/no parity/1 stop bit. Because of the time it takes for the RFC-1 to try voice communications first, set your modem for a 90 second wait for carrier. This is done by typing "ATS7=090". Also, disable busy-signal detection and error correction by typing "ATX2&Q0".

 